sinee — 7.11 F10 Group: Communication Function Parameter

EM600 High-Performance Vector Control Inverter User Manual As shown in Figure 7-30, communication interval △ t refers to the period from previous receipt of valid data frame by slave (inverter) to its receipt again. If △ t is greater than set time (see F10.03; this function is disabled if it is set as 0), this is called “communication overtime”. 1# 2# 3# 1# △ t Send Return Return Send Return Send Return Figure 7-30 Communication Overtime Application example: If master must send data to a slave (for example #1) within a certain time T, then user can enable communication overtime function for #1 slave by setting F10.03>T.

No fault report for communication overtime will be triggered during normal communication. However, if master does not send data to #1 slave for a time period T and this condition is maintained for a time set by F10.03, then a communication fault ( E16 ) will be reported to notify personnel of “#1 slave communication fault”, so that the personnel may conduct troubleshooting. ★ The time set by F10.03 must be greater than T, but must not be excessive, otherwise running of inverter under fault condition for a long time can result in adverse effects. ★ F10.03 should be 0.0 (disabled) usually. It’s useful only for continues communication in order to monitor the status of communication.

Define the time interval from receipt of valid data frame 1 by inverter, to data learning, and then to starting data return, as response delay (t w2 ). To ensure that the protocol chip works stably, response delay shall be set as 1 ms to 20 ms (no 0). If communication data involves EEPROM, actual response delay will be extended to “EEPROM action time + F10.04”. 1: valid data frame: sent by external master to inverter, and function code, data length and CRC are correct. As shown in Figure 7-31, data sending section (t s ), sending end mark section (t w1 ), 75176 forwarding waiting section (t w2 ), data return section (tr) and 75176 receipt section (t w3 ).

195 Function Name of Parameter Description Unit Default Property Code Function Code F10.03 Communication Overtime 0.0 - 60.0, 0.0: Disabled (also works for master - slave system) s 0.0 ● Function Code Name of Function Code Parameter Description Unit Default Property F10.04 Modbus Response Delay 1 - 20 ms 2 ●