EM600 High-Performance Vector Control Inverter User Manual F13.08=1: AI1 F13.08=2: AI2 F13.08=3: AI3 F13.08=4: AI4 (Expansion Card) Under torque control mode, upper limit frequency is set through AI (percentage) * F13.09. F13.08=5: High-Frequency Pulse Input (X7) Under torque control mode, upper limit frequency is set through HDI (percentage) * F13.09. Please refer to the description of F00.04 for detailed explanations of AI1-AI4 and X7. F00.04 has the same meanings as AI1-AI4 and X7. 100.00% is the percentage inputted through F13.09 (Upper Limit Frequency of Torque Control). F13.08=6 or 7: Communication Setting Torque is determined by communication, etc.
If inverter is under master-slave communication control (F10.05=1) and present inverter is a slave (F10.06=0), set upper limit frequency is “700FH (Master-Slave Communication Setting) * F10.08 (Receiving Proportionality Factor of Slave)* F00.18 (Upper Limit Frequency)”. Range of 700FH is -100.00% to 100.00%. See Table 12-2 for details. For general communication (F10.05=0) a) If F13.08=6 upper limit frequency is 700BH (Upper Limit Frequency Percentage Setting of Torque Control) * F13.09 (Upper Limit Frequency of Torque Control) b) If F13.08=7 upper limit frequency is 7018H (Upper Limit Frequency Setting of Torque Control) Range of 700BH is 0.00% to 200.00%.
Range of 7018H is 0.00% to F00.16 (Maximum Frequency).See Table 12-2 for details. In driving an object, motor must overcome the static/kinetic friction. Setting this group of parameters can enable the torque to rotate as per the specified torque after having overcome the inherent static/kinetic friction force. The static friction prevails before motor runs, but the kinetic friction prevails after motor runs. All in all, this group of parameters is related to motor capacity performance. This group of parameters can be interpreted like this:
when actual frequency (or estimated frequency if inverter is in SVC control; or PG card feedback frequency if inverter is in FVC control mode) is less than or equal to the value set through F13.11, then output torque is “set frequency + F13.11 Static Friction Torque Compensation Factor”. When actual frequency is greater than the value set through F13.11, output torque is “Set Torque + F13.13 Kinetic Friction Torque Compensation Factor”. The greater compensation factor is, the higher the compensation level will be. The percentage of the compensation factor is equal to the torque setting percentage.
211 Function Parameter Name of Function Code Unit Default Property Code Description F13.11 Static Friction Torque Compensation 0.0 - 100.0 % 0.0 ● F13.12 Static Friction Compensation Frequency Range 0.00 - 50.00 Hz 1.00 ● F13.13 Kinetic Friction Torque Compensation 0.0 - 100.0 % 0.0 ●