EM600 High-Performance Vector Control Inverter User Manual 7.15 F14 Group: Motor 2 Parameter EM600 inverter can be switched between two motors. User may perform motor nameplate parameter settings, motor parameter tuning, selection of VF control or vector control, related parameters of encoder, and parameters related to VF control or vector control performance for these two motors respectively. Motor parameters of the second group are listed in F14, with function codes having the same meanings as that of the first group.
F14.00 - F14.34 correspond to F01.00 - F01.34 and they are respectively motor nameplate parameter, motor parameter, encoder parameter, etc.; F14.35 corresponds to F00.01, for motor control mode; F14.36 - F14.76 corresponds to F06.00 - F06.40, as vector control parameters; F14.77 refers to acceleration/deceleration options for motor 2. In the following, only F14.77 is described. For other parameters, please refer to relevant parameter of Motor 1. F14.77=0 , acceleration/deceleration time of motor 2 is the same as that of motor 1. Refer to description of F15.03 - F15.09.
F14.77=1/2/3/4, acceleration/deceleration time of motor 2 is fixed as acceleration/deceleration time 1, 2, 3 and 4, which correspond to F00.14 - F00.15/F15.03 - F15.04/F15.05 - F15.06/F15.07 - F15.08 respectively. 7.16 F15 Group: Auxiliary Function As indicated in Figure 7-32, if FJOG/RJOG is enabled, inverter will start running at the frequency by F15.00; after it is disabled, inverter will stop as per stop mode. When inverter is running, F15.01 and F15.02 are set as acceleration and deceleration time. However, set values (for example 500) have different meanings and ranges, depending upon time unit (F15.13).
If F15.13=0, it means that acceleration/deceleration time is 5.00s; if F15.13=1, it means that acceleration/deceleration time is 50.0s. 212 Function Name of Function Parameter Description Unit Default Property Code Code F14.77 Motor 2 Acceleration /Deceleration Time 0: Same as Motor 1 1: Acceleration/Deceleration Time 1 2: Acceleration/Deceleration Time 2 3: Acceleration/Deceleration Time 3 4:
Acceleration/Deceleration Time 4 0 〇 Function Name of Function Parameter Description Unit Default Property Code Code F15.00 JOG Frequency 0.00 - Maximum Frequency F00.16 Hz 5.00 ● F15.01 JOG Acceleration Time 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 5.00 ● F15.02 JOG Deceleration Time 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 5.00 ●