sinee — 7.16 F15 Group: Auxiliary Function

EM600 High-Performance Vector Control Inverter User Manual Output Frequency Acceleration/ Deceleration Time Reference Frequency F15.09 Jog Running Disabled Jog Frequency F15.00 Jog Running Enabled t 0 Actual Acceleration Time Actual Deceleration Time Jog Acceleration Jog Deceleration Time Figure 7-32 Jog Running For JOG running mode, user may independently set frequency and acceleration/deceleration time, which shall not be shared but not having the same physical meaning with normal running. Trigger applications for JOG running command depend upon inverter control modes. See Table 7-20 for details.

Time F15.01 F15.02 Table 7-20 JOG Running Command 213 Command Source Options (F00.02) JOG Running Command M th 0: Keypad Control ru ★ .K (F12.00) can be set as “1: FJOG” or “2: RJOG”. Press M.K , en JOG running command is enabled; release M.K , then JOG nning command is disabled. Remove keypad during JOG running to stop inverter. N de 1: Terminal Control co co umeric input terminal function “4: FJOG” or “5: RJOG”. Under fault applications, if function terminal is enabled, JOG running mmand is active; if function terminal is disabled, JOG running mmand is inactive. If 2: Communication re Control co ru host controller writes “0003H: FJOG” or “0004:

RJOG” in the gister 7000H through MODBUS protocol, JOG running mmand will be active; writes “0007H: coast to stop”, JOG nning command will be inactive. Function Name of Function Parameter Descriptio n Unit Default Property Code Code F15.03 Acceleration Time 2 0.00 - 650.00 (F15.13= 0.0 - 6500.0 (F15.13=1 0 - 65000 (F15.13=2) 0) ) s 15.00 ● F15.04 Deceleration Time 2 0.00 - 650.00 (F15.13= 0.0 - 6500.0 (F15.13=1 0 - 65000 (F15.13=2) 0) ) s 15.00 ● F15.05 Acceleration Time 3 0.00 - 650.00 (F15.13= 0.0 - 6500.0 (F15.13=1 0 - 65000 (F15.13=2) 0) ) s 15.00 ●