sinee — 7.16 F15 Group: Auxiliary Function

EM600 High-Performance Vector Control Inverter User Manual Analog quantity level detection can be used to detect and monitor present setting of F15.25 and also for internal operation, external alarm monitoring, etc. Two detection applications can be set, but the detection is only for one analog quantity input channel. Analog Quantity AI % Detection Level Hysteresis 0 Output Terminal t (s) Disabled Disabled Enabled 0 t (s) Figure 7-38 ADT Detection As indicated in Figure 7-38, detection level has been set with a valid start point.

When analog quantity of input has been processed for offset and after this, its percentage is greater than detection level, function ADT is enabled; if applications for “disable” are determined by monotonic deceasing hysteresis, when transformation result of input analog quantity is reduced to a value below “Detected Level - Hysteresis”, function ADT is disabled. Energy consumption brake is a brake method by transforming electric energy generated during speed reduction into heat energy of braking resistor to realize rapid brake. It applies 218 Function Name of Function Code Parameter Description Unit Default Property Code 3:

AI4 (Expansion Card) F15.26 Analog Quantity Level Detection ADT1 0.00 - 100.00 % 20.00 ● F15.27 ADT1 Hysteresis 0.00 - F15.26 (Monotonic decreasing is active) % 5.00 ● F15.28 Analog Quantity Level Detection ADT2 0.00 - 100.00 % 50.00 ● F15.29 ADT2 Hysteresis 0.00 - F15.28 (Monotonic decreasing is active) % 5.00 ● Function Code Parameter Name of Function Code Unit Default Property Description F15.30 Energy Consumption Brake 0: Disabled 1: Enabled 0 〇 F15.31 Operation Voltage of Energy Consumption Brake 120.0 - 140.0 (380V,100.0=537V) % 128.5(690V) ● F15.32 Brake Duty Ratio 20 - 100 (100 means that duty ratio is 1) % 100 ●