EM600 High-Performance Vector Control Inverter User Manual This function code refers to setting of acceleration/deceleration time while inverter is in “rapid stop”. 7.17 F16 Group: User Defined Function Parameter EM600 inverter has the fixed length count function (refer to Figure 7-40). Inverter must input length information via numeric input terminal in the form of pulse before setting relevant function codes to complete length count function. Completion information of final length count can be outputted via numeric output terminal and other methods for other purposes (for example, input it via DI/VX to be used as stop command). User may also view present length count value through F18.34.
Pulse count per meter a (0.1 - 6553.5) p/m F18.34 Length Length Pulse DI 揕 ength Count? Input (Function of No.37) ≥ Sensor Divider Comparer HDI 揜 apid Length Count? Input (Function of No.38) Clear Set Length 1 (1- 65535) m Reset Length Clear Signal DI 揕 ength Clear? Input (Function of No.38) Figure 7-40 Block Diagram of Fix Length Count Function Principle of work: Length detection sensor transforms length information into pulse information; DI terminal collects input pulse number N; according to setting of “Pulse N l , and then compare it with Count per Meter” as , we can know that length is 1 “Set Length” l .
If 1 l l , it means that length has not reached set value; otherwise, this function is completed. “39: Length Clear” is used to clear count and reset output signal. If pulse frequency is greater than 250 Hz (=1/(2(default filter times)*2*1ms -1 )), please complete input via X7 and set F02.06 as “38: High-Speed Length Count Input”. 250 Hz is just a theoretical value. Actual value will apply. To avoid any mistake, please use high speed pulse input terminal.
221 Name of Function Code Function Code Parameter Description Unit Default Property F15.40 Deceleration Time at Rapid Stop 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 1.00 ● Name of Function Function Code Parameter Description Unit Default Property Code F16.01 Set Length 1-65535 (F16.13=0) 0. 1-6553.5 (F16.13=1) 0.01-655.35 (F16.13=2) 0.001-65.535 (F16.13=3) m 1000 ● F16.02 Pulse Count Per Meter 0.1 - 6553.5 100.0 ● F16.03 Set Count Value F16.04 - 65535 1000 ● Pulse count CntIn Length 11 Lgth DO 揕ength Reach? Output (Function of No.16) Length Reach Signal