EM600 High-Performance Vector Control Inverter User Manual 239 Fault Fault type Cause Troubleshooting Code E23 Keypad EEPROM Fault 1. Interference results in reading and writing errors of EEPROM. 2. EEPROM damaged.E 1. Press STOP/RESET to reset and then try it again. 2. Seek for technical support. E24 Autotuning Fault 1. Press STOP/RESET in parameter autotuning. 2. In autotuning, the external coast-to-stop terminal FRS=ON. 3. Motor is not connected. 4. Motor is not disconnected from load on rotational autotuning. 5. Motor fault. 1. Press STOP/RESET to reset. 2. Check the connection between inverter and motor. 3. Motor is disconnected from load on rotational autotuning. 4. Check motor.
E25 Motor Overspeed Protection 1. No PG card is connected. 2. Encoder Line Number (F01.25) is not set correctly. 3. AB Phase Sequence (F01.27) is incorrect. 4. Actual motor speed is lager than set speed of inverter or load pulls motor in an opposite way due to excessive load. 1. Connect to PG card or replace control mode with V/F control mode. 2. Set encoder line number as per the user manual of the encoder. 3. exchange encoder AB wiring sequence. 4. Reduce load or select another inverter and motor that are one speed level higher. E26 Offload Protection 1. Enabled when motor current is lower than offload detection level F07.25 and this status is maintained for the time set through F07.26. 2.
Current detection module is damaged. 1. Load is excessively light or offload level is not reasonable. 2. Offload. 3. Seek for technical support. E27 Accumulated Power-On Time Reach 1. Set power-on time reach. 1. Contact dealer. E28 Accumulated Run Time Reach 1. Set run time reach. 1. Contact dealer. E29 Internal Communication Fault 1. Internal SPI communication fault. 1. Power-on after power cut. 2. Seek for technical support. E33 CANopen Communication Overtime 1. Data Communication Overtime. 1. Ensure that inverter is powered on again after the line is smooth. E34 DeviceNET without Network Power Supply 1. No DC24V Power Supply is detected for DeviceNET bus. 1. Power supply backs to normal.