EM600 High-Performance Vector Control Inverter User Manual When inverter has a fault above, press STOP RESET to reset or use fault reset terminal to exit fault status; after the fault is cleared, inverter returns to function setting status; if the fault fails to be cleared, LED will continue to display present fault data. Corresponding number is shown as below on reading fault by communication. ‘E’ of E11 and its subsequent failure is omitted. For example, correspingding number of ‘E11’ is ‘11’. Check List of Capitalized English Letters Displayed:
After power is on, due to improper function setting and incorrect wiring between inverter and external control terminals, motor can not meet expected working requirements. Fault analysis as described in this chapter can be taken as the reference to take corrective actions. If trip codes appear, see 9.1 for corrective actions to clear the trips. 240 Fault Fault type Cause Troubleshooting Code E35 DeviceNET BUS-OFF 1. Short circuit between CAN H and CAN L of _ _ DeviceNET bus. 1. Ensure that wiring is normally. E36 DeviceNET MACID Detection Error 1. There is already a same station on the bus. 1. Power on inverter after address modification. E37 DeviceNET IO Communication Overtime 1.
NO IO message received within specified time during online status. 1. Ensure that inverter is powered on again after line is smooth. E38 DeviceNET IO Mapping Error 1. IO Polling Data Address. 1. Make sure to input correct parameter address. E39 Profibus-DP Parameterizatio n Data Error 1. Incompliance of parameterization data sent by master with specification. 1. Make sure to receive correct parameterization data. E40 Profibus-DP Configuration Data Error 1. Configuration data sent by master is not supported by slave card. 1. Make sure to receive correct configuration data. E41 Profibus-DP IO Disconnection 1.
At normal data exchange status, DP card has not received any data for a long time (disconnection between DP card and master), so it exists from data exchange status. 1. Enter data exchange status restoration fault. 0 SC HOC HOU SOC SOU SLU ILP OLP OL OH 0 1 2 3 4 5 6 7 8 9 10 a b C D E F G H I l A B C D E F G H I L N O P Q r S T U x Y N O P Q R S T U X Y