sinee — 12.4.3 Modbus Response Delay

EM600 High-Performance Vector Control Inverter User Manual marks. Therefore, as indicated in Figure 12-1 or Figure 12-3, an idle level with transmission time equal to or greater than 3.5 characters is defined as start or end mark, and transmission will be deemed as abnormal if there is an idle level with transmission time greater than 1.5 characters during message transmission. Specific start-end or abnormal interval time has something to do with bit rate (refer to Table 12-5).

If bit rate is 9,600 bps, with sampling period of 1ms, then start-end interval is an idle level greater than or equal to 4ms (3.5Ч10/9600=3.64≈4), the interval of exceptional data is the idle level with interval time among bits of one data frame greater than or equal to 2ms (1.5Ч10/9600 = 1.56≈2) but smaller than 4ms (idle level between normal data bits less than or equal to 1 ms).

Table 12-5 Checklist of Time Interval and Bit Rate (when t modify =1 ms) Frame 1 Frame 2 Frame 23 Abnormal Frame Normal Frame t0 At least 3.5 >1.5 characters At least 3.5 3.5 characters characters Figure 12-3 Correct and Incorrect Data Frames characters 4.5 characters 12.4.2 Data Frame Processing After receiving a data frame, the system shall process it first to judge whether it is a legal frame. Then, check whether data is correct and perform corresponding processing. If the received frame is illegal, inverter will not turn data; if the received frame is legal but incorrect, it will turn corresponding fault information frame. Legal frame:

meet address (inverter or broadcast) and length (not less than 3) applications. Correct frame: a correct frame is a legal frame, of which corresponding memory address is correct, memory content is in defined scope and can be processed for the time being. 12.4.3 Modbus Response Delay Define the time interval from receipt of a valid data frame [7] (data on RS-485 network, different from command sent by keyboard), to data learning, and then to starting data return, as response delay (set through F10.04).

Since a standard protocol has defined start and end marks, there must be response delay, at least 3.5 character time interval +1ms (485 protocol chip stable time, t w2 ), and minimum time interval has something to do with bit rate. If bit 268 Bit rate Start-end interval Abnormal interval Remarks (bps) T (t ) interval modify T (t ) abnormal modify 4800 8 4 Normal frame permits the idle point level ≤3ms; when an idle level≥8ms, it means the end of a data frame. 9600 4 2 Normal frame permits the idle point level ≤1ms; when an idle level≥4ms, it means the end of a data frame. 19200 2 1 Normal frame permits idle point level< 1ms; when an idle level≥2ms, it means the end of a data frame.

Higher 1 1 An idle level of 1ms means the end of a data frame.