EM630/TC6A Closed-Loop Vector Hoist Inverter User Manual 3.3.6 Wiring of Multi-function Output Terminal Y1 and Y2 can be powered by internal 24V or external supply. See Figure 3–17. EM630 +24V 24V EM630 +24V 24V Y1.Y2 Relay Y1.Y2 COM COM Relay + - D C a. Internal power supply b. External power supply Figure 3–17 Wiring of Multi-function Output Terminal 1. An antiparallel diode must be added, in order to use an internal power supply (as shown in Figure 3–17-a). 3.3.7 Analog Output Terminal Wiring External analog table of analog output terminals M1 and M2 may indicate multiple physical quantities. Select (0 - 20mA) or (0 - 10V) by DIP switch; M1 corresponds to S2; M2 corresponds to S3.
The wiring of DIP switch and terminal is as follows: 3.3.8 Wiring of Communication Terminal Communication terminals A+ and A- are RS485 communication interfaces of the inverter. Realize the networking control of the host controller (PLC or PLC controller) and the inverter by connecting to the host controller for communication. RS485 and RS485/RS232 are connected to EM630 inverter as shown in Figure 3–18, Figure 3–19 and Figure 3–20. RS485 terminal of single inverter directly connects to the host controller for communication: 45 EM630 M1 M2 GND V I S2 M1 for analog voltage output M1 for analog current output V I S3 M2 for analog voltage output M2 for analog current output