sinee — EM730 User Manual

User Manual of EM730/EM730E Series Inverter When the motor drives an object to move, it is necessary to overcome static/dynamic friction. You can set this group of parameters to enable the motor rotation at the specified torque while overcoming the inherent static/dynamic friction. The motor is mainly subject to static friction before rotation and dynamic friction after starting rotating. In short, the output performance of the motor is related to this group of parameters. The specific description of this group of parameters is as follows:

“when the actual frequency (estimate frequency in SVC) is less than or equal to the set value of F13.12, the output torque is the ‘se set torque + F13.11 static friction torque compensation’; ; and when the actual frequency is greater than the set value of F13.12, the output torque is ‘se set torque + F13.13 dynamic friction torque compensation’”. T ”. The larger the compensation value, the stronger the compensation force will be. The compensation percentage is equal to the torque setting percentage. 7.15 Parameter Group of Motor 2 of F14 group The two motors of the EM730/EM730E series inverter can be switched.

For the two motors, the motor nameplate parameters, encoder parameters and VF control or vector control parameters can be set separately, and the VF control or vector control can be selected independently. In addition, the parameters of the two motors can be tuned separately. codes are defined the same as those in the first group.

The function codes F14.00 to F14.34 All motor parameters in the second group are included in the F14 group, and the function correspond to F01.00 to F01.34, which are motor nameplate parameters, motor parameters and encoder parameters; the function code F14.35 corresponds to F00.01, which is used to select the motor drive mode; the function codes F14.36 to F14.76 correspond to F06.00 to F06.40, which are vector control parameters; and the function code F14.77 is used to select the acceleration/deceleration time of the motor 2. Only the parameters of F14.72 are described below. For the rest of the parameters, refer to the relevant parameters of the motor 1.

250 compensation F13.12 Frequency range of static friction compensation 0.00 - 50.00 Hz 1.00 ● F13.13 Dynamic friction torque compensation 0.0-100.0 % 0.0 ●