sinee — EM730 User Manual

User Manual of EM730/EM730E Series Inverter F14.77=0 : the acceleration/deceleration time of the motor 2 is the same as that of the motor 1. For details, see the description of the function codes F15.03 to F15.09; F14.77=1/2/3/4 : the acceleration/deceleration time of the motor 2 is fixed as the acceleration/deceleration time 1/2/3/4, corresponding to the function codes F00.14, F00.15/F15.03, F15.04/F15.05, F15.06/F15.07 and F15.08, respectively. See F00.16 and F00.18 252 of F14.52, the weaker the speed PID regulation is. Function code F14.77 Acceleration/deceler ation time options of motor 2 0: the same as motor 1 1: acceleration and deceleration time 1 2:

acceleration and deceleration time 2 3: acceleration and deceleration time 3 4: acceleration and deceleration time 4 0 〇 Function Default Function code name Parameter description Unit Attribute code setting F14.78 Maximum frequency of motor 2 20.00~600.00 Hz 50 〇 F14.79 Upper frequency limit of motor 2 Lower limit frequency F00.19 to maximum frequency F14.78 Hz 50 ● Function Default Function code name Parameter description Unit Attribute code setting F14.80 V/F curve setting of motor 2 0: straight line V/F 1: multi-point broken line V/F 2: 1.3-power V/F 3: 1.7-power V/F 4: square V/F 5: VF complete separation mode (Ud = 0, Uq = K * t = voltage of separation voltage source) 6:

VF semi-separation 0 〇