User Manual of EM730/EM730E Series Inverter The system has four groups (F00.14 and F00.15 in the first group) of acceleration and deceleration time options to meet different needs for normal operation. After completing the setting, the user can switch them via the combination of digital input functions “19: acceleration and deceleration time terminal 1” and “20: acceleration and deceleration time terminal 2”. For details, please see: Table 7-6 Function List of Multi-function Digital Input Terminals.
Output frequency frequency of acceleration and deceleration time Fundamental F15.09 Set frequency 0 Actual acceleration time Actual deceleration time Time t Set deceleration time Set acceleration time Fig.
7-33 Schematic Diagram of Acceleration and Deceleration Time 255 Function Default Function code name Parameter description Unit Attribute code setting F15.03 Acceleration time 2 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.04 Deceleration time 2 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.05 Acceleration time 3 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.06 Deceleration time 3 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.07 Acceleration time 4 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.08 Deceleration time 4 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.09 Fundamental frequency of acceleration and deceleration time 0:
maximum frequency F00.16 1: 50.00Hz 2: set frequency 0 〇