User Manual of EM730/EM730E Series Inverter EM730/EM730E series inverters have a fixed-length counting function, as shown in Fig. 7-40. The length counting function is performed by entering the length information from the digital input terminal in the pulse form and then setting the related function code. The final length count information can be outputted by the digital output terminal for other purposes (e.g. DI/VX input as the stop command). Users can also view the real-time length count via F18.34. The length resolution can be set by F16.13. In case of any change in the length resolution, F16.01 will change accordingly.
For example, if F16.13 is set to 0:1m, the setting range of F16.01 is 1-65535m. DI “length count” input 37# Pulses per meter α (0.1~6553.5) p/m F18.34 “Length reached” signal Length information Sensor Divider Comparator Length pulse information HDI “high-speed length count” input 38# function function output 16# function Clear to 0 ≥ DO “length reached” Reset Set length 1 (1-65535)m Length clear signal DI “length clear” input 38# function Fig. 7-40 Block Diagram of Fixed-length Counting Principle of fixed-length counting: The length detection sensor converts the length information into pulse information. The DI terminal collects the number N of input pulses.
N l The length 1 is calculated based on the set function code “Pulses per meter” and 267 Default Function code Function code name Parameter description Unit Attribute setting F16.01 Set length 1 - 65535 (F16.13=0) 0.1 - 6553.5 (F16.13=1) 0.01 - 655.35 (F16.13=2) 0.001 - 65.535 (F16.13=3) m 1,000 ● F16.02 Pulses per meter 0.1 - 6553.5 100.0 ● F16.13 Set length resolution 0:1m 1:0.1m 2:0.01 m 3:0.001m 0 〇 Pulse count CntIn Length 11 Lgth