User Manual of EM730/EM730E Series Inverter then compared with the “Set length” l . If 1 l l  , it means that the length does not reach the set value; otherwise, the fixed-length count is completed. The “39: Clear length” input can be applied to clear the count and reset the output signal. When the pulse frequency is greater than 250Hz (=1/(2 (default filtering times)*2*1ms -1 )), make sure of the input from the high-speed pulse input terminal (X5) and set F02.06 to “38: high-speed length count input”. 250Hz is only a theoretical value. The actual effect will prevail. In order to avoid errors, use the high-speed pulse input terminal wherever possible.

2 1 3 4 5 6 7 8 9 10 11 Count value 2 1 3 4 5 6 7 8 9 9 0 0 Pulse input Invalid Valid Clear input Reach the length Invalid Valid Invalid Fig. 7-15 Example of Fixed-length Counting Fig. 7-15 shows an example, where F16.01=2 and F16.02=4.0. When the length count is 8 (=2Ч4), the “16: length reached” output will be valid. When the “39: clear length” input is valid, the count will be cleared, and the “16: length reached” output will be invalid. EM730/EM730E series inverters support counting, as shown in Fig. 7-42. Pulse information is inputted from the digital input terminal. When the count reaches the specific value, the there will be the corresponding valid signal output.

The user can use this signal for programming (e.g. DI/VX input as the stop command) or view the real-time count by F18.33. 268 Default Function code Function code name Parameter description Unit Attribute setting F16.03 Set count value F16.04 - 65535 1,000 ● F16.04 Specified count value 1 - F16.03 1,000 ●