User Manual of EM730/EM730E Series Inverter be valid. When the count reaches the set value 8, the output of “14: reach the set value” will be valid. When the input of “36: clear length” is valid, the count will be cleared to 0, and the outputs of “15: reach the specified value” and “14: reach the set value” will be invalid. Limit65535 ≥ set count ≥ specified count≥0. If the set count and specified count are 0, the counter function will be invalid. This function is allowed for one terminal only at a time. function code other than 0. When the running time reaches the set time, the inverter will be shut Regular running function:
The regular running function can be enabled by setting this down, and the terminal output of the option “26: reach the set time” will be valid, and there will be a prompt indicating that the inverter has been run for the set time. running time by the input function “27: clear regular running time” (i.e. resetting F18.35). This Users can view the remaining time of regular running by F18.35, or clear the current represents the set time in the non-running status and remaining time in the running status. That is, one regular running process lasts from start to stop, and the accumulated time in the non-running status will be cleared. Agent password.
★ After this password is set, the inverter may fail to work normally. Be careful to set this password. Set the total cumulative power-on time. If the cumulative power-on time (F12.15) reaches or exceeds the total cumulative power-on time (F16.07), please contact the agent for maintenance. ★ After this parameter is set, the inverter may fail to work normally. Be careful to set this parameter.
270 Default Function code Function code name Parameter description Unit Attribute setting F16.05 Set time of regular running 0.0-6500.0, 0.0 is invalid min 0.0 ● Default Function code Function code name Parameter description Unit Attribute setting F16.06 Agent password 0 - 65535 0 〇 Function Default setting Function code name Parameter description Unit Attribute code F16.07 Setting of cumulative power-on arrival time 0-65535; 0: disable the protection when the power-on time is up h 0 〇