User’s Guide for EM760 series high-performance vector inverter 53 F00.09 Reference options of auxiliary frequency source B in main and auxiliary operation 0: relative to the maximum frequency 1: Relative to main frequency source A 0 F00.10 Gain of main frequency source 0.0~300.0 % 100.0 ● F00.11 Gain of auxiliary frequency source 0.0~300.0 % 100.0 ● F00.12 Synthetic gain of main and auxiliary frequency sources 0.0~300.0 % 100.0 ● F00.13 Analog adjustment of synthetic frequency 0: synthetic frequency of main and auxiliary channels 1: AI1 * synthetic frequency of main and auxiliary channels 2: AI2 * synthetic frequency of main and auxiliary channels 3:
AI3* synthetic frequency of main and auxiliary channels 4: AI4* synthetic frequency of main and auxiliary channels 5: High frequency pulse (PULSE) * synthetic frequency of main and auxiliary channels 0 F00.14 Acceleration time 1 0.00~650.00 (F15.13=0) 0.0~6500.0 (F15.13=1) 0~65000 (F15.13=2) s 15.00 ● F00.15 Deceleration time 1 s 15.00 ● F00.16 Maximum frequency 1.00~600.00 Hz 50.00 F00.17 Options of upper frequency limit control 0: set by F00.18 1: AI1 2: AI2 3: AI3 4: AI4 (expansion card) 5: high frequency pulse input (X7) 6: Communication setting (percentage) 7:
Communication setting (direct frequency) 0 F00.18 Upper frequency limit Lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 ● F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ● F00.20 Running direction 0: consistent direction 1: opposite direction 0 ● F00.21 Reverse control 0: Allow forward/reverse running 1: Prohibit reversing 0 F00.22 Duration of forward and reverse dead zone 0.00~650.00 s 0.00 ● F00.23 Carrier frequency 1.0-16.0 (rated power of the inverter: less than 4kW) kHz 2.0 ●