User’s Guide for EM760 series high-performance vector inverter 65 F05.09 Rise time of VF separation voltage 0.00~60.00 s 2.00 ● F05.10 Compensation gain of V/F stator voltage drop 0.00~200.00 % 100.00 ● F05.11 V/F slip compensation gain 0.00~200.00 % 100.00 ● F05.12 V/F slip filtering time 0.00~10.00 s 1.00 ● F05.13 Oscillation suppression gain 0~20000 100 ● F05.14 Oscillation suppression cutoff frequency 0.00~600.00 Hz 55.00 ● F05.15 Droop control frequency 0.00~10.00 Hz 0.00 ● F05.16 Energy saving rate 0.00~50.00 % 0.00 ● F05.17 Energy saving action time 1.00~60.00 s 5.00 ● F05.18 Flux compensation gain of synchronous motor 0.00~500.00 % 100.00 ● F05.19 Filtering time constant of flux compensation of synchronous motor 0.00~10.00 s 0.50 ● F05.20 Change rate of VF separate power supply setting –50.00~50.00 % 0.00 ● F06 Vector control parameter group F06.00 Speed proportional gain ASR P1 _ 0.00~100.00 12.00 ● F06.01 Speed integral time constant ASR T1 _ 0.000~30.000 0.000:
no integral s 0.250 ● F06.02 Speed proportional gain ASR P2 _ 0.00~100.00 10.00 ● F06.03 Speed integral time constant ASR T2 _ 0.000~30.000 0.000: no integral s 0.300 ● F06.04 Switching frequency 1 0.00 to switching frequency 2 Hz 5.00 ● F06.05 Switching frequency 2 Switching frequency 1 to maximum frequency F00.16 Hz 10.00 ● F06.07 Filtering time constant of speed loop output 0.000~0.100 s 0.001 ● F06.08 Vector control slip gain 10.00~200.00 % 100.00 ● F06.09 Upper limit source selection of speed control torque 0: set by F06.10 and F06.11 1: AI1 2: AI2 3: AI3 4: AI4 (expansion card) 5: Communication setting (percentage) 6: Take the maximum values of AI2 and AI3 7:
Take the minimum values of AI2 and AI3 0 F06.10 Upper limit of speed control motor torque 0.0~250.0 % 165.0 ●