sinee — EM760 User Manual

User’s Guide for EM760 series high-performance vector inverter 69 F06.66 Asynchronous motor type selection 0: Built-in permanent magnet synchronous motor 1: Surface-mounted permanent magnet synchronous motor 2:

Permanent magnet direct drive motor 0  F06.67 Excitation current MTPA calculation gain 0.0~300.0 % 20.0 ● F06.68 Excitation current flux weakening calculation gain 0.0~300.0 % 20.0 ● F06.69 Start compensation angle 0~360 ° 0  F06.70 Expanded counter electrodynamic potential filtering factor 1 0.000~1.732 0.279 ● F06.71 Expanded counter electrodynamic potential filtering factor 2 0.000~1.732 0.578 ● F06.72 Minimum estimated frequency of synchronous motor SVC 0.01~100.00 HZ 0.50  F06.73 Low frequency band ID-specific gain 0~500.0 % 100.0 ● F06.74 Smooth switching times 1~1000 20 ● F06.75 Speed toggle-hold times 1~2000 100 ● F06.76 Low-speed correction factor of stator resistor of asynchronous motor 10.0~500.0 % 100.0 ● F06.77 Low speed correction factor of rotor resistor of asynchronous motor 10.0~500.0 % 100.0 ● F06.78 Slip gain switching frequency of asynchronous motor 0.10~Fmax Hz 5.00  F06.79 Speed ring differential time constant ASR Td1 _ 0.000~10.000 S 0 ● F06.80 Speed ring differential time constant ASR Td2 _ 0.000~10.000 S 0 ● F06.81 Speed ring differential limit 0.0~150.0 % 0 ● F06.82 Filtering time constant of bus voltage 0.0~1500.0 ms 8.0 ● F07 Protection function setting group F07.00 Protection shield E20 E22 E13 E06 E05 E04 E07 E08 00000000  0:

valid protection 1: shielded protection F07.01 Motor overload protection 0.20~10.00 1.00 ●