User’s Guide for EM760 series high-performance vector inverter 83 F15.36 Switching options of PWM modulation mode 0: invalid (7-segment PWM modulation) 1: valid (5-segment PWM modulation) 0 F15.37 Switching frequency of PWM modulation mode 0.00 to maximum frequency F00.16 Hz 15.00 ● F15.38 Options of dead zone compensation mode 0: no compensation 1: compensation mode 1 2: compensation mode 2 1 F15.39 Terminal jog priority 0: Invalid 1:
valid 0 F15.40 Deceleration time for quick stop 0.00~650.00 (F15.13=0) 0.0~6500.0 (F15.13=1) 0~65000 (F15.13=2) s 1.00 ● F15.41 Output power display coefficient 50.00~150.00 % 100.0 ● F15.42 Output current display coefficient 50.00~150.00 % 100.0 ● F15.43 Output voltage display coefficient 50.00~150.00 % 100.0 ● F15.44 Current reaches the detection value 0.0~300.0 (100.0% corresponds to the rated current of motor) % 100.0 ● F15.45 Current reaches the hysteresis 0.0~F15.44 % 5.0 ● F15.46 Torque reaches the detection value 0.0~300.0 (100.0% corresponds to the rated torque of motor) % 100.0 ● F15.47 Torque reaches the hysteresis 0.0~F15.46 % 5.0 ● F15.48 Divided frequencies of encoder 1~256 1 ● F15.49 High-frequency filtering coefficient of PG card 0~255 0 ● F15.62 PG card feedback frequency filtering time 0.000~30.000 S 0.010 ● F15.63 Speed reaches the rising limit 0.00~Fmax HZ 30.00 ● F15.64 Speed reaches the filtering time 0~60000 Ms 500 ● F15.65 Speed reaches the falling limit 0.00~Fmax HZ 0.00 ● F15.66 Overcurrent detection level 0.1-300.0 (0.0:
no detection; 100.0%: corresponding to the rated current of motor) % 200.0 ● F15.67 Overcurrent detection delay time 0.00~600.00 s 0.00 ● F15.68 Market Local electricity 0.00~100.00 1.00 F15.69 Power-frequency load factor 30.0~200.0 % 90.0