User’s Guide for EM760 series high-performance vector inverter 84 F16 Customization function group F16.00 Industry application 0: Universal General purpose model 3: Winding and unwinding application 0 F16.01 Set length 1~65535 (F16.13=0) 0.1~6553.5 (F16.13=1) 0.01~655.35 (F16.13=2) 0.001~65.535 (F16.13=3) m 1000 ● F16.02 Pulses per meter 0.1~6553.5 100.0 ● F16.03 Set count value F16.04~65535 1000 ● F16.04 Specified count value 1~F16.03 1000 ● F16.05 Set time of regular running 0.0~6500.0, 0.0: Invalid min 0.0 ● F16.06 Agent password 0~65535 0 F16.07 Setting of cumulative power-on arrival time 0~65535, 0:
disable the protection when the power-on time is up H 0 F16.08 Setting of cumulative running arrival time 0~65535, 0: disable the protection when the running time is up H 0 F16.09 Factory password 0~65535 XXXXX ● F16.10 Analog output percentage when the set length/design count is 0 0.00~100.00 % 0.00 F16.11 Analog output percentage when the set length/design count is the set value 0.00~100.00 % 100.00 F16.13 Set length resolution 0:1m 1:0.1m 2:0.01m 3:0.001m 0 F16.14 Slot 1 type 0: No card 1: PROFINET card 2: EtherCAT card 3: CANopen card 4~9: Reserved 10: Gain Incremental encoder PG card 11: Gain Incremental encoder PG card with UVW 12: Rotary transformer PG card 13:
SinCos PG card 14: Gain Incremental encoder PG card with divided frequency 15~19: retention 20: IO expansion card 1 21~29: retention XXXX ×