The setting items and their commands are shown below. Table 4.5.4-3 List of manual color correction setting values For ICM or None, the commands for manual color correction are not sent. Examples of these commands are shown below. Example 1: When the type of color correction is set to Epson vivid color ^XA ^S(CPC,C,V Set color correction type to Epson vivid color ^S(CPC,R,0 Set brightness to 0 ^S(CPC,A,0 Set saturation to 0 ^S(CPC,O,0 Set contrast to 0 ^S(CPC,N,0 Set tone (cyan) to 0 ^S(CPC,M,0 Set tone (magenta) to 0 ^S(CPC,L,0 Set tone (yellow) to 0 ^XZ Example 2:
When the type of color correction is set to ICM or None ^XA ^S(CPC,C,D Set color correction type to None Manual color correction commands not sent ^XZ Epson ESC/Label Application Development Guide CW-C8000 Series Rev. B Page 33 Item Setting range Default setting Command Brightness -25 to +25 0 ^S(CPC,R Saturation -25 to +25 0 ^S(CPC,A Contrast -25 to +25 0 ^S(CPC,O Tone (cyan) -25 to +25 0 ^S(CPC,N Tone (magenta) -25 to +25 0 ^S(CPC,M Tone (yellow) -25 to +25 0 ^S(CPC,L