Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

CHASSIS MODIFICATIONS 2-86 E URO C ARGO E URO 4 - 5 2.21.8 Harness Modifications due to Changes to Wheelbase or Overhang Should it be necessary to lengthen the wires on the chassis owing to the new dimensions of wheelbase and overhang, a watertight junction box must be used which has the same characteristics as those used on the standard vehicle. The components used such as wires, connectors, terminal blocks, conduits etc. must be of the same type as those used originally and be correctly fitted.

2.21.9 Power Draw-off at a Voltage Different from that of the System If a 12 V power supply is required from a 24 V system, a suitable voltage adapter must be installed for drawing power from the normal circuit. Power must not be drawn from one battery only due to the detrimental effects this would have on the batteries during recharging. 2.21.10 Battery Main Isolation Switch (optional ) IGC: This is generally located on the battery box and is manually operated. Single-pole type: when switched, disconnects the battery from the on-board system, leaving the body computer, bunk lights, refrigerator, radio and Webasto timer working, along with the tachograph, as required by the law. TGC:

Switching off can be performed by opening the doors or operating a key switch, or by switching on the overhead lights, tail lights, hazard lights, operating the electric hatch, the auxiliary heater timer, the TGC ON key on the instrument panel. For special bodies (e.g. for transporting fuel, dangerous goods, etc.), a specific ADR standard switch is required. Operations on the electrical system Base - July 2006 Revi - June 2007 Print 603.93.431