Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

POWER TAKE-OFFS 4-13 E URO C ARGO E URO 4 - 5 PTO management 4.6 PTO management Operations which do not comply with the instructions specified by IVECO or made by non qualified personnel can cause severe damage to on-board systems, effect driving safety and good operation of the vehicle and cause considerable damage which is not covered by warranty. ! Figure 4.6 115534 4.6.1 Introduction Two operations are required to operate a PTO: 1. Mechanical PTO engagement; 2. PTO mode to be associated to the PTO. See below for PTO mode definitions. The expression ”PTO active” indicates that the PTO is engaged and that one of the PTO modes is active. Otherwise, it is said that the PTO is engaged only.

Actions 1) and 2) can be carried out separately, in the sequence 1) - 2), or by means of a single control using the PTO switches on the central console in the cab (as explained below). In general, the PTO can be engaged by an electrical control (operated by a solenoid valve). ! It is important to use the signals available on the bodybuilders connectors (e.g. parking brake applied, stationary vehicle signal, reverse gear not engaged) to ensure correct PTO management and avoid possible damage to the vehicle’s mechanisms. These signals must exclusively be taken from the bodybuilders connections. PTO management Print 603.93.431 Base - July 2006 Revi - June 2007