Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

SPECIFIC INFORMATION AND INSTRUCTIONS 5-7 E URO C ARGO E URO 4 - 5 21 pin connector (brown color): ST 13 It is located inside the cab, on the passenger side, in the electronic unit compartment. The function of the terminals is described in Table 5.1. Spare part Order number for male-holding coupling (AMP): 41200685 Spare part Order number for female-holding coupling (type MCP 2,8): 504163549 Note: For inputs activated by an earth switch, the earth on the ST13 pin 17 connector must be used. Note: For inputs activated by a +24V switch, the socket under key switch K15 on the ST13 pin 11 connector must be used.

Table 5.1 - 21 pin connector ST 13 Bodybuilder connectors Print 603.93.431 Base - July 2006 Revi - June 2007 Connections Pin Descr i p tion Type Wire code Max.

load Remar ks 1 Engine Start INPUT 8892 10 mA Close to ground = start engine (signal must be permanently active till engine starter runs) Open wire = no action 2 Engine Stop INPUT 0151 10 mA Close to ground = stop engine (short activation sufficient to stop engine) Open wire = no action 3 Service brake OUTPUT 1165 200 mA +24V with service brake pressed 4 Vehicle standstill OUTPUT 5515 200 mA +24V with vehicle stationary 5 Parking brake High side OUTPUT 6656 200 mA +24V with parking brake engaged 6 Reserved 7 Vehicle speed OUTPUT 5540 10 mA Pulse Signal 8 Engine status High side OUTPUT 7778 150 mA +24V at engine running 9 Gearbox neutral High side OUTPUT 8050 200 mA +24V with neutral engaged 10 Reverse gear High side OUTPUT 2268 150 mA +24V with reverse gear engaged 11 K15 POWER 8871 3 A K15 12 CC Set+ INPUT 8156 10 mA CC Set + input Open wire = Set + not activated Close to Ground = Set + activated 13 CC Set- INPUT 8157 10 mA CC Set- input Open wire = Set — not activated Close to Ground = Set — activated 14 CC OFF INPUT 8154 10 mA CC OFF input Open wire = Off not activated Close to Ground = OFF activated 15 CC Resume INPUT 8155 10 mA CC Res input Open wire = RES not activated Close to Ground = RES activated 16 CC OFF intermedi- ate OUTPUT Tbd 200 mA Connection for CC OFF from the switch on the steering column (switch normally closed to ground)