Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

SPECIAL INSTRUCTIONS FOR EUROCARGO -SCR- EXHAUST SYSTEMS 6-10 E URO C ARGO E URO 4 - 5 6.4.2 Operations on the AdBlue tank Figure 6.8 114740 As regards the AdBlue tank, ensure that:

- the tank ventilation pipe is never closed; - after each operation, the tank contains at least 5 l of AdBlue so as to guarantee the cooling of the dosing module; - after each operation, the tank does not contain more than 85% of AdBlue (corresponding to the max reading of the level sensor) with respect to the tank total volume, so as to guarantee enough room for AdBlue to expand during freezing at temperatures below -11 ° C; - the AdBlue intake point inside the tank is always below the minimum level; - the AdBlue return point inside the tank is always above the maximum level; - when fitting equipment onto the chassis, there is enough room for the AdBlue fill gun to fit completely and correctly into the tank filler.

Figure 6.9 114741 1. Tank ventilation - 2. Residual air - 3. Return line in tank - 4. Temperature sensor - 5. Tank level - 6. Inlet line in tank - 7. Tank minimum - 8. Tank heater Distribution of the main SCR system components fitted onto the vehicle Base - July 2006 Revi - June 2007 Print 603.93.431