Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 3.2 General usage for definitions and symbols. To make this handbook easier to read for those who will need to refer to it only infrequently, an attempt has been made to devise a mathematical notation which is more self-explanatory than the notations used in other recent reports related to hardness assurance. This notation is used in the definitions listed in this section and throughout the rest of the handbook.
As an example of the differences, the present notation uses MEAN(PAR) and GMEAN(PAR) for the measured arithmetic and geometric mean values, respectively, of a parameter; in several other reports an overline on the word PAR is used to indicate the arithmetic mean value and PAR M is used to denote the geometric mean value. Conversions to the other notations, if necessary, should present no difficulties. The following is a list of specific definitions: Absorbed dose - The absorbed energy usually expressed in rads. c(lower case) - The acceptance number in a sample size series test.
Confidence level - The chance of rejecting a lot where there is less than probability P that any part from the lot can pass the test condition. Device specification - The contractual document to which an electronic device is either sold or purchased. Diffusion lot - A set of wafers heated at one time in one diffusion furnace. Dose - See Ionizing Radiation Dose. Dose Rate - Rads per second due to ionizing radiation. Exp(x) - Napier’s constant, e, to the x-th power. Please note that an exponent can only be a pure number.
Therefore, if the notation shows a variable that has a dimension (such as an ionizing radiation dose expressed in rads, for example) as an exponent, it should be understood that the exponent has been made dimensionless by dividing it by a quantity having a value of one but with the same dimensions as the variable in question. Fluence - The accumulated number of irradiating particles per square centimeter. Goodness of fit - The degree to which a measured probability distribution fits the assumed distribution; the CHI- square test is commonly used to determine the goodness of fit. Gray - 10,000 ergs of absorbed energy per gram; equals 100 rads.
i(lower case) - The subscript used to label the i-th device in a sample of devices. I(upper case) - The subscript used to label the I-th lot in a sample of lots. In-flux - Measurements made on a device while it is being irradiated. Ionizing radiation dose - The accumulated absorbed energy in rads or Grays due to ionizing radiation. JAN parts - JAN parts are listed in the Qualified Manufacturers List (QML) and undergo scheduled periodic audits by the qualifying activity to MIL-M-38510, MIL-PRF-19500, MIL-PRF-38534, and MIL-PRF-38535 requirements. TL (n, C,P) - One-sided tolerance limit. This factor takes into account the certainties resulting from small sample size statistics.
It is applied to normal distributions as follows: For a sample size n, if MEAN(PAR) and STDEV(PAR) are the measured mean and standard deviation respectively for parameter PAR, then with confidence C, there is probability P, that future measurements of the parameter PAR will be less than: MEAN(PAR) + K TL (n, C, P) * STDEV(PAR) Or larger than: MEAN(PAR) - K TL (n, C, P) * STDEV(PAR) SUPERSEDES PAGE 6 OF MIL-HDBK-816 6