Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 not uncommon occurrence) then, in the data analyses that are performed, the sample size effectively becomes the number of lots and not the number of parts tested. 5.1.4.4 Sample sizes in characterization report. The number of samples to be tested, for each vendor, is to be included in the characterization report and in the test plan. TABLE III. Device identity information. a. Device identification number b. Generic part number c. JAN part number (if applicable) d. Name of the manufacturer e. Lot date code f. Lot number (wafer lot number, if applicable) g. Wafer number (if applicable) h. Serial number (for each device) i.

Package type j. Special selection criteria (if applicable) 5.1.5 Device identity number and pedigree. Serious problems in analyzing data have also been experienced because the device that was tested was not adequately identified. The information needed to establish an adequate device identity is shown in table III. This information should be recorded in the characterization report. As discussed in 5.1.7.5 on data format, a subset of the table III information should be included when the actual test data is recorded and tabulated in the characterization report.

It should be recognized that radiation response characteristics, especially for ionizing radiation dose, can be very sensitive to processing conditions. Thus, to the maximum extent practicable, all processing steps and equipment should be documented for the lot under test. Whenever possible also, the lot under test should be a wafer lot, because a wafer lot is defined as one for which all processing steps are the same and performed with the same equipment. In the case of JAN class S or MIL-PRF-38535, class V devices, wafer identity is also available and should be recorded. 5.1.6 Selection of radiation environments.

The characterization report and the test plan should identify the radiation environments, such as neutrons; ionizing radiation dose (total dose) and dose rate, also the type of radiation, i.e., whether electrons, gamma rays, protons, etc., and heavy ions or protons SEU, the radiation facilities, and the levels that will need to be used for the testing. This step should precede that of selecting the test parameters to ensure that no parameters are overlooked which might be especially sensitive to a particular radiation environment.

For the two radiation environments of principal interest here, namely neutrons and ionizing radiation dose, the effects are expected to be independent and characterization measurements can be made separately for the two environments. If the effects from two environments are expected to depend on each other, as for example, temperature effects on dose rate induced latch-up, or ionizing radiation dose effects on SEU sensitivity, then each part will have to be exposed to both environments.

If the given part type is known to be very hard to a particular radiation environment as, for example, an MOS device may be to neutrons, then characterization measurements for that type of radiation may be omitted. Careful consideration should be given, however, to the possibility that intentional or parasitic sensitive elements (e.g., bipolar devices in the MOS example cited) may be present in the device. 5.1.7 Selection of test parameters. All the parameters that are to be measured need to be selected and listed in the test plan. Normally, for QML parts, the subset of group A electrical parameters that are known to be sensitive to the selected radiations will be used.

In some instances, the change in the value of a parameter is more significant than the absolute value of the parameter. For those cases, the test plan should specify that the change, or delta, in the parameter value be measured. 5.1.7.1 Test conditions and parameters to be recorded. The parameters or circuit functions that need to be measured will have to be identified and listed in the report and in the test plan along with the experimental conditions under which the measurements are to be made. The specified conditions should include both the nominal and the worst case conditions under which each parameter should be measured.

They should also include such quantities as, bias voltages, operating frequencies, and ambient temperatures before, during, and after irradiation. For the worst case measurements, the report should contain recommendations on how such conditions SUPERSEDES PAGE 17 OF MIL-HDBK-816 17