Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 may be derived or at least bracketed (circuit analyses may be required to arrive at worst case conditions). This section of the report may also be used to identify, for each parameter that is to be measured, what value of the parameter constitutes device failure. Such definitions are needed in connection with the fluence to failure measurements recommended earlier for permitting estimates of design margin to be made for particular applications. Failure may be either parametric failure, loss of functionality, or degradation to the point where the device can no longer be used.
5.1.7.2 Objectives of the test conditions and parameters. The selection of test conditions and test parameters will depend on the objectives of the test, time and budget constraints, and, possibly, other factors. For each test, however, the information listed in table IV should be recorded in the characterization report. As is discussed in 5.1.7.5 on data format, a subset of the table IV information should be included when the actual data is tabulated and recorded in the characterization report. Experience gained by the DNA sponsored ERRIC is the basis for most of the recommendations contained in these guidelines regarding data requirements and format. 5.1.7.3 Narrative information.
The narrative information listed in the table IV is used to provide a further description of the device and the test conditions required for each test. 5.1.7.4 Symbols. A partial list of military standard symbols for particular device parameters and the corresponding symbols used by ERRIC is given in appendix A. A standard list which all users have agreed to use does not exist for device parameters. As a result, different symbols are sometimes used by different organizations for the same device parameter. ERRIC can receive data labeled in any way and uses a narrative comment as part of the data storage to make sure the device parameter is properly identified.
If data processing programs are used for analyzing the behavior of particular parameters, provision should be made for recognizing some limited set of the symbols for the parameter in question in addition to those given in appendix A. 5.1.7.5 Specification of a data format. Although data format would appear to be a simple matter, past experience has shown that severe difficulties can be encountered, particularly with computerized data analysis programs, if a standardized data format is not used to record the data.
Because the accumulation of radiation response information in a centralized data bank can help avoid duplication of such measurements and is therefore highly desirable, the data format recommended here is the one used by ERRIC. TABLE IV. Pre- and post-irradiation measurement information. a. Name and organization of test engineer. b. List of equipment used for measurements and calibration procedures. c. Description of test procedures or test standards used. d. Electrical test date. e. Test number. f. List or table of electrical test parameters and corresponding bias conditions; (note that the pre-rad bias conditions should be used for the post-rad measurements) g.
A complete time history of the individual irradiations and the post-irradiation measurements (especially necessary for ionizing radiation dose (total dose) because of time dependent effects) h. Ambient and/or case temperature. i. Sample size. j. Electrical measurement results for each parameter. k. Narrative information. 5.1.7.5.1 Definition of a test number in ERRIC. In ERRIC, a unique test number is assigned to both the pre- and post-rad measurements that are made on a single parameter under a single set of bias or operating conditions, for all devices in the sample, and for all the radiation fluences used.
The information which is common to a unique test number and which can be used therefore as the heading for that test number is listed in table V. Pre- and post-rad test results obtained for all the sample devices that are covered by the same heading are then listed under a single test number. Table VI shows an example of how ERRIC data is recorded. For test number 2 and subsequent tests made on the same devices and for the same irradiation conditions, the first three lines of the heading need not be repeated. Thus, the data for test number 2 could be recorded as in table VII. SUPERSEDES PAGE 18 OF MIL-HDBK-816 18