Department of Defense MIL-HDBK-816 Notice 1 — MIL-HDBK-816 Notice 1 Radiation Hardness Assurance Guidelines Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 TABLE V. Example of ERRIC test data. Test number: 1 ; Test date: 10-21-85 Type of radiation: Neutrons; Radiation facility: PMI Device type: DAC-08; Manufacturer: ABC; Lot date code: 8429 Parameter: IREF; Units: mA Test conditions and narrative information: a. Bit high speed multiplying D/A converter (device description included only for test number 1). b. Reference bias current (parameter description). c. V+ = 15 V, V- = -15 V. d. Measured 24 hours after the end of the irradiation. Measurement data Device Radiation level serial PRE-RAD 2.00E12 6.00E12 1.00E13 number 0271 2.00 2.00 2.00 2.00 0272 2.00 2.00 2.00 2.00 . . . . . . .

. . . . . . . . . . . . . TABLE VI. Information common to a unique test number in ERRIC. a. Single type of radiation and corresponding test facility b. Single part type c. Single manufacturer d. Single test date (post-rad) e. Single lot date code f. Single wafer lot number (if available) g. Single parameter measured and associated bias or operating conditions h. Narrative information (should include information about the irradiation conditions and time history of the irradiations and the electrical measurements) 5.1.8 Test plan. Figure 3 (see 5.1.1.1) and table II (see 5.1.1.1) show the major steps involved in characterizing the radiation response of a part.

Also shown are the steps which are included in the test plan. The test plan should, as a minimum, address the pre-irradiation measurements to be made, the irradiations to be performed, the post irradiation measurements to be made, and, finally, should specify the data documentation requirements and format. 5.1.8.1 Advantages of a good test plan. The development of a detailed test plan is recommended as a way to make characterization measurements efficient. A good test plan will minimize costs by specifying the data set which will meet the objectives of the measurements and by optimizing the use of radiation test facilities and part samples.

The test plan should also facilitate subsequent data analysis by specifying a data format which will be easy to use and will protect against inadvertent omission of required data points by providing a check list for the measurements. REPRINTED WITHOUT CHANGE. 19