Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 TABLE VII. ERRIC data format for test number 2 in a series. Test number: 2 ; Test date: 10-21-85 Repeating test information: Same as lines 2 and 3 for test number 1 Parameter: IZS; Units: mA Test conditions and narrative information: a. Zero scale current (parameter description) b. V+ = 15 V, V- = -15 V. c. Time of measurements referred to the end of the irradiation. Measurement data Device Radiation level serial Pre-rad 2.00E12 6.00E12 1.00E13 number 0271 4.20E-5 2.00E-5 6.50E-5 1.67E-4 0272 -2.00E-6 4.70E-5 9.00E-5 2.54E-4 . . . . . . . . . . . . . . . . . . . . 5.1.8.2 Pre-irradiation measurements and data examination.
If the pre-irradiation characteristics are measured, the measurements should be made according to the conditions listed in table IV (see 5.1.7.2) and recorded in the format given in table VI (see 5.1.7.5.1) and table VII (see 5.1.7.5.1). The data should be examined to make sure that there are no bad measurements, devices or data outliers in the sample. This examination is important to keep bad data from being entered into the report. If bad or anomalous data are taken, this fact together with an explanation of why the data is not being used should be recorded in the characterization report even if the data are not sent to ERRIC or some other data bank.
The annual books of ASTM standards, listed in 2.2, contain many of the test methods that can be used for making radiation response measurements. 5.1.8.3 Caution. Caution should be exercised when devices are handled, particularly with regard to pin alignment in the holding fixture and when the devices are attached to the test circuit. Bias voltages should be off during attachment. ESD handling procedures should be observed for the class of parts being tested. 5.1.8.4 Irradiation conditions. The irradiation conditions and the reasons for selecting them should be discussed in detail in the characterization report and summarized in the test plan.
The information to be included in the test plan is listed in table VIII. The various questions that need to be addressed in selecting the irradiation conditions are discussed in the sections which follow.
For each of the selected radiation environments, the plan should include the test facility selected, the responsible organization and personnel, recommended dosimetry techniques, the maximum fluence or ionizing radiation dose to be reached (whenever possible, the radiation levels should be high enough so that most of the test devices can be made to fail), and whether device measurements will be made “in-flux”, i.e., while the device is being irradiated, or whether a series of discrete irradiations with measurements following each irradiation will be made.
In the latter case, which is sometimes called step stress testing, the test plan should specify the number of irradiations to be made and the ionizing radiation dose or fluence for each irradiation in the series. Because time dependent effects can be very important, especially for ionizing radiation dose, a complete time history of the irradiations and the post-irradiation or in-flux measurements should be recorded. This time history should include the start and stop times of both the irradiations and the measurements as well as the rate at which the ionizing radiation dose was delivered.
The test plan should state, whenever possible, that a standard irradiation test method should be used and give the appropriate reference. REPRINTED WITHOUT CHANGE. 20