Downloaded from https://www.everyspec.com MIL-HDBK-704-3 3. Apparatus. The test equipment should be as follows: a. Adjustable AC power supply (rotating AC source for current waveform limits) b. True RMS voltmeter c. Frequency counter d. Power meter e. Spectrum analyzer f. Distortion meter g. Current transformer h. Oscilloscope 4. Test setup. Configure the test setup as shown in figure TAC101-1. Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. Current measurements must be taken from the 115 Volt conductors.
If the utilization equipment performance specification document imposes current waveform limits, the AC power source must be a rotating machine. 5. Compliance test. With the power source off, install the UUT and the stimulation and monitoring equipment into the test setup of figure TAC101-1. Turn on the power source and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Close the circuit breaker, energizing the UUT. Record the inrush currents (oscilloscope traces) and record the maximum rms current of each phase in the data sheet shown in table TAC101-II.
Allow sufficient time for the UUT to warm up. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. Record the frequency in table TAC101-II. For each phase, record the voltage, VA, and power factor in the data sheet shown in table TAC101-II. Compare the calculated percent inrush current, the load unbalance, and power factor with the limits of the applicable edition(s) of MIL-STD-704. Repeat for each mode of operation of the UUT. Confirm the UUT does not use half-wave rectification and record in the data sheet shown in table TAC101-II.
If the utilization equipment performance specification document imposes current waveform limits, for each phase record the total current distortion and current spectrum in the data sheet shown in table TAC101-II and compare to the limits defined in the utilization equipment performance specification document. Repeat for each mode of operation of the UUT. 7