Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 NOTE: 1. The indicated maximum flux density is calculated at a distance of 7.5 meters based upon cables with an outside diameter of 50 millimeters (mm). The length of the cable run is 1.25 meters and the dc magnitude is 1,500 A (750 A per cable). FIGURE 50. Typical effects of excessive cable separation in a quad arrangement. 6.2.5 Concentric cable Concentic cable has an inner conductor with its center on the axis of an annular or cylindrical conductor that carries current in the reverse direction. The stray magnetic field from such a cable should be very small. In principle, we minesweeping cable runs.

would think concentric cable would be ideal for There are, however, problems in using it for large currents: (a) Only one concentric cable should of one minesweeping generator. be used to carry the full output (b) The problem of unequal current division between. parallel conductors results if two or more concentric cables are used in parallel 90