NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 3.3.2.5 Magnetic material between two current loops of opposite polarity Now suppose we have a steel bulkhead symmetrically located between two equal and opposite current loops (see figure 7). An end view will look like the bulkhead shown in which 1, 2, 3, and 4 represent the conductors carrying current in the long direction of the current loops.

The arrows diverging from point P represent roughly, in magnitude and direction, the magnetic fields that would be produced at this point by the currents in the four conductors if no magnetic material were present Note that the vertical component vanishes along the centerline of the bulkhead and that the horizontal component is not large. Magnetizing a bulkhead in the direction of its length or width, either of which can be considerable, will give rise to a substantial stray magnetic field. Magnetizing the bulkhead in the direction of its thickness, which is small, should not give rise to a very large magnetic field.

We should expect, therefore, that magnetic material symmetrically placed between two equal and opposite current loops (see figure 7 (A)) will be less harmful than if it were between two current loops of the same polarity (see figure 6 (A)). Note, however, that there will be a vertical component if the steel bulkhead is not symmetrically located between the equal and opposite current loops but is closer to one than the other. For this reason, it is desirable that magnetic material be kept as far as possible from the current loops in the batteries or cable runs, and that in no case should it be disposed as shown on figures 6 (A) and 7 (A). FIGURE 7.

Steel bulkhead flanked by two current loops, (A) top view. (B) end view. 3.3.3 Shielding. Cable runs through a compartment will be a source of stray magnetic field during normal operation. In the optimum configuration to reduce stray magnetic field, cable runs will be configured with a number of cables per run that is a positive power of 2 (i.e. 2, 4, 8, ... cables). Of those cables half of them will carry the current in one direction and the remaining cables will carry current in the opposite direction. However, even where the optimum configuration for cable runs is employed, some stray field will occur.

This occurs because of the fact that all of the cables in a run will not simultaneously be energized with the same magnitude of current. In these instances, we would consider shielding the stray field. This procedure involves enclosing the cable run in a structure made of ferromagnetic material. If we choose a material with a large relative permeability, then the magnetic signature of the enclosure would not change appreciably with the variation of the stray field within it.