Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 3 .3.3.1 Shielding effectiveness. The shielding effectiveness of a ferro- magnetic material is a function of the magnetic permeability of the material. We can determine the shielding effectiveness, in decibels (dB), from the following: where: S =- shielding effectiveness. B = the magnetic field of the source inside the shielded volume measured at point P outside the shielded volume (see figure 8). BO = the magnetic field of the source at the point P if a shield were not present (see figure 8). 3.3,3.1.1 Using relative permeability to approximate shielding effective. ness.
We know that relative magnetic permeability can be approximated from the magnetic fields as follows: where. Pr = the relative permeability of the material. Because of this relationship we can determine the approximate shielding effective- ness of a material simply by knowing its relative permeability. Therefore, the shielding effectiveness, in decibels, could be approximated by the following: 6