NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com FIGURE 22. Three different dipole arrangements. The preceding table shows clearly the decrease in stray magnetic field that is obtained by going from a single uncompensated current loop to an opposing pair, and the still greater decrease that is obtained by going from one opposing pair to two opposing pairs. Note also that the decrease is greater with increasing depth, as shown in table II. TABLE II. The effects of increasing depth on magnetic field. 4.3.2 General information on formulas. 4.3.2.1 Convenience.

In order to estimate the stray magnetic field from an array of current loops, we must be able to calculate the magnetic field produced by several current loops This can always be done by calculating the magnetic field produced by each loop individually and adding the results. Such a process is slow and time consuming, however, and furnishes no immediate answer to the two questions of primary interest, namely, the position of the point or points where the vertical component of magnetic field has its maximum value, and the magnitude of the maximum value.

Rather than calculating the magnetic field individually for each dipole in a group, it is more convenient to use the approximate formulas given in 4.3,3 when they are applicable. Note, however, that they are limited to symmetrically arrays of current loops or dipoles which all have magnetic moments of equal magnitude. When the dipoles are not arranged symmetrically or are not of equal strength, the formulas do not apply and it will be necessary to estimate the magnetic field in other ways. 37