Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 set would be used to compensate the stray magnetic field produced by the field current of the generator; the other, the stray magnetic field produced by the armature current of the generator.
(e) Install some regulatory system that would respond to changes in the generator field and armature currents and automatically adjust the stray magnetic field degaussing coil currents so as to compensate the stray magnetic field from the generator We may have to use this arrangement to compensate for generators that have already been built, installed in ships, and found to have large stray magnetic fields, but which cannot be modified without a large expenditure of time and money. This arrangement should, however, be scrupulously avoided in new design. It is completely contrary to the principle of simplicity. 5.3.2 Example of extreme simplicity.
Consider a minesweeping cable run vith four single-conductor cables. If the cable arrangements are such that the polarities are as follows: + - + - then the stray magnetic fields generated by the cable run will be large; if, however, the cables are rearranged to change the polarities as follows: + - - + then the resulting stray magnetic field will be small. In the first case, we have two current loops that produce stray magnetic fields that add; in the second case, we have two current loops that produce stray magnetic fields that oppose. The stray magnetic field is significantly reduced by simply changing the connection of the cables.
The cable run’s performance is not affected by the change, and no additional equipment was required to reduce the stray magnetic field. This is an excellent example of the principle of simplicity. In many cases, extreme simplicity cannot be attained; but the example given illustrates the goal to be approached as closely as possible. 5.3.3 le of simplicity in field poles of generators and motor. Another illustration of the principle of simplicity is furnished by the cancella- tion of magnetic fields produced by the field poles of dc generators and motors.
For machines with four or more poles, the magnetic fields produced by the poles cancel to an extent that increases with increasing number of poles No additional coils need be added for the sole purpose of compensation. This is accomplished by the field poles themselves, which are indispensable for the operation of the machine. To be sure, we may have to use more poles than would be needed if stray magnetic field is not a consideration, but this is an increase in the number of elements of the same kind rather than the addition of elements of a different kind.
It illustrates the application of the principle of simplicity in a case where we are unable to attain the extreme simplicity of a cable run with four cables 73