101 Frequency Converters and Motors In general it is common to use abbreviations in the diff erent legislative frameworks and the standards to describe the safety function and the safety level. Table 3.15 General FC safety functions and their functionality Function Description Illustration Safe Torque Of f STO The motor does not get energy to produce torque/ rotation. This function complies to stop category 0 according to IEC 60204-1. Activation of STO Frequency Actual frequency Time Safe Stop 1 SS1 A controlled stop, in which the drive elements of the machine are kept energised in order to stop it. The power is only disconnected when standstill has been reached.
This function complies to stop category 1 according to IEC 60204-1. Activation of STO Frequency Actual frequency SS1 time supervision Time SS1 time Safe Limited Speed SLS A safe state of speed is called Safe Limited Speed. This ensures that a machine runs at a constant safe speed. If it runs faster a Stop function will be activated SLS activated Frequency Actual frequency SLS max. speed limit Time Safe Maximum Speed SMS Ensures that the machine does not run at a higher level than a def nied maximum speed. It prevents machine damage and reduces hazards. Function-wise it is the same principle as SLS SMS always active Frequency Actual frequency SMS max.
speed limit Time Safe Speed Monitor SSM SSM monitors for zero speed and sets an output signal high if zero speed is reached. This function can be used to unlock doors or simply to display that the machine is in standstill. Standstill output active Frequency Actual frequency Speed motor limit Time