100 Frequency Converters and Motors Two temperature monitoring methods are implemented in the FC, in order to protect the motor: Calculation: The motor temperature is calculated based on a mathematical motor model Measurement: Thermistors or PTCs placed inside the motor can be connected to the device, to monitor temperature If motor overheating occurs, the remedial action required is programmed to fi t the application needs. 3.8 Functional Safety Functional safety defi nes protection against hazards caused by incorrect functioning of components or systems. In Europe, functional safety falls under the Machinery Directi- ve 2006/42/EC.
The Machinery Directive describes the purpose of functional safety as follows: “Machinery must be designed and constructed so that it is fi tted for its function, and can be operated, adjusted and maintained without putting persons at risk when these operations are carried out under the conditions foreseen but also taking into account any reasonably foreseeable misuse thereof.” Depending on which application standard has to be fulfi lled, the system must reach a defi ned safety level. The required safety level is defi ned through the risk assessment. The Machinery Directive refers to diff erent standards, according to the safety level required.
The European functional safety regulations are comparable to many others around the globe. For example, in North America the OSHA (Occupational Safety and Health Act) applies, and in Canada the CCOHS (Canadian Centre for Occupational Health and Safety) provide the framework for applying safety measures. Although the relevant standards diff er between the various regions, the safety principles are closely related. Safety Level Abbreviation Standard Category Cat EN 954-1 Performance Level PL EN ISO 13849-1 Safety Integrity Level SIL IEC 61508 / IEC 62061