99 Frequency Converters and Motors T Fig. 3.13 T/N characteristics with and w/o external cooling Alternatively, instead of providing extra cooling, it is possible to reduce the motor load ratio. To reduce the motor load ratio, select a larger motor. However, the FC specifi cation imposes limits on the size of motor that can be connected. When the motor current is non-sinusoidal, the motor receives harmonic currents that increase the motor temperature, as shown in Fig. 3.14 Maximum continues torque and current shape relation. The magnitude of the harmonic currents determines the amount of heat increase.

Therefore, do not operate a motor continuously at 100% load when the current is non-sinusoidal. Fig. 3.14 Maximum continues torque and current shape relation When the application predominantly requires low speeds, an additional fan to cool the motor is recommended to ensure full torque. However, the fan should be powered from a separate supply and should not be connected to the output of the FC. As an alternative to air, liquid can be used for cooling the motor. Liquid cooling is typically implemented in special motor designs.