98 Frequency Converters and Motors 3.7 Motor Heating and Thermal Monitoring Energy lost in motors during operation will warm up the motor. If the motor is heavily loaded, some cooling is needed. Depending on the system, motors can be cooled in diff erent ways: • Self-ventilation • Forced air cooling • Liquid cooling To maintain the motor lifetime, keep the motor within the specifi ed temperature range. The most common cooling method is self-ventilation, where the motor is cooled by a fan mounted on the shaft. The temperature conditions of the motor are subject to two infl uences: • When the speed decreases, the cooling air volume also decreases.
• When a non-sinusoidal motor current is present, more heat is generated in the motor. At low speeds the motor fan is not able to supply enough air for cooling. This problem arises when the load torque is constant throughout the control range. This lower ventilation determines the permissible level of torque during continuous loading. When the motor runs continuously at 100% rated torque, at a speed which is less than half the rated speed, the motor requires extra air for cooling. This extra air cooling is indicated by the shaded areas in Fig. 3.13 T/N characteristics with and w/o external cooling.