125 Electromagnetic Compatibility The noise source is the voltage source inverter that produces a pulse-shaped output voltage with very short rise- and fall times (also expressed as high du/dt). This voltage is applied across parasitic capacitances to ground in the motor cable and motor results in a common-mode current: I cm = C cm Ч du dt where C cm is the parasitic capacitance to ground. The common-mode current needs to close the loop and return to its source, the DC- link. Controlling the return path of the common-mode current is a key element of keeping electromagnetic interference under control.

Inside the FC there are common- mode capacitors – that means capacitors between the FC circuit and ground/earth. The common-mode capacitors can be found in the RFI circuit (C cm1 ) or as decoupling capacitors in the DC-link (C cm2 ). If a shielded motor cable is used and the motor end of the cable is connected to the motor chassis and the FC end is connected to the FC chassis then, ideally, the common mode current will return to the DC link via the common-mode capacitors. The common-mode current returning through the mains supply is unwanted because it can cause interference in other equipment connected to the mains.

Therefore this current must be minimised, for example by using RFI fi lters. When unshielded motor cables are used, then only a part of the common-mode current returns through the FC’s chassis and common-mode capacitors thus causing more interference on the mains grid. Immunity Immunity, as well as noise emission need be considered in a FC application. The control signals connected to a FC can be quite susceptible to noise. In general, analogue signals are more susceptible than digital signals. Therefore it is better to use digital bus communication instead of analogue reference signals.

If analogue signals cannot be avoided, a 4 – 20 mA current reference signal is preferred to a 0 – 10 V voltage reference signal because it is less susceptible to noise. 5.3 Grounding and Shielding Grounding Grounding means to connect electrical equipment to a common reference ground or earth. There are two reasons for doing this: