174 Sizing ad Selection of Frequency Converters and temperature. Most FC manufactures off er these solutions to minimize the eff ect of the environment: • Mount the FC’s in a central cabinet with long motor cables. In this way the FC’s are remote from the critical environment • Install air-conditioning in the control cabinet that ensures critical environment does not contact the FC’s and other electronics. (Positive-pressure). • Some FC’s are fi tted with a cold plate. With this solution you can place the FC inside a cabinet and via the cold plate the heat is transmitted to the outside.

Then the FC’s electronics are kept away from the critical environment • Use a FC which is fi tted with a sealed enclosure. FC manufacturers today off er an enclosure ingress protection up to IP66/Nema 4X which will protect the electronics from the outside environment and eliminates the cost of a separate enclosure • Order the FC’s with conformal coating which will signifi cantly improve protection against chlorine, hydrogen sulphide, ammonia and other corrosive environments Fig. 9.8 Printed circuit board with conformal coated The FC is mostly used by professionals of the trade as a complex component forming part of a larger appliance, system, or installation.

Therefore note that the responsibility for the fi nal EMC and harmonics properties of the appliance, system or installation rests with the installer who has to ensure compliance with the local regulations. For details about EMC and harmonics please refer to chapter 5 Electromagnetic Compatibility and chapter 7 Mains Interference.