Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk HU32 Series Linear Solenoid Push or Pull Type 1) Other voltages are available on request up to 230 V DC Weight: Complete solenoid: appr. 55 g Armature: appr. 11 g Standard: Voltage: 24 V DC Flying leads: 10 cm Insulation class: E (max. permissible temperature = 120 ° C) HU 324 - F 24 V DC 100% ED Long life expectancy through plastic bobbin armature bearing 2) If solenoid is mounted directly onto a flat metal surface of at least 100 cm 2 , the duty cycle can be extended up to 1.3 x nominal rating Document LNSHU3/12 Revision 00 2 10 %ED 8 F/N 5 4 2 5 0,8 1 15 Force vs.
Stroke diagram F = f (s) 0,5 25 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature 0,3 40 0,2 100 stroke s = 0 corresponds to armature in fully home position 0,1 0 1 2 3 4 7 5 6 s/mm Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
HU 32 0 – F – 24 V DC 100 % ED Ord er specifications HU Line ar solenoid 32 Size s Desi gn type 0 Pull type solenoid 4 Thrust type solenoid Coil terminals F Flying leads (10 cm standard length) A Push-on connector (optional) 24 No minal voltage (standard voltage)1) 100 % ED Per m. duty cycle under air cooled conditions (LK) 100 40 25 15 5 % Perm. duty cycle (ED)2) 4,2 10 16 25 64 W Nominal coil power Pn 17 6 ms Actuation time (ED)
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk HU32 Series Linear Solenoid Push or Pull Type 20 6 Dimensions given with armature in fully home position Direction of stroke 20 6 0,5 18 Document LNSHU3/22 Revision 00 2 21 Dimensions given with armature in fully home position Direction of stroke Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Series HU 320 pull type solenoid M3 8 ≤0,5 2 10 16 18 Ø2 12 3,5 32 41 12 3,5 Series HU 324 thrust type solenoid M3 16 10 Ø8 8+1 M3 12 32 15 ±0,3 48 12 Ø8 32 8+1 15 ±0,3 M3 48