fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Basic software procedures 5.1.5 Switching on the ID indicator For easy identification of the server, switch on the ID indicator, especially when working in a datacenter environment or a server room. The ID indicator can also be activated via the iRMC web interface and its status is reported to the BMC. I For more information, see section "Locating the defective server" on page 47 or the "ServerView Suite Local Service Concept (LSC)" and iRMC user guides. Using the ID button on the front panel К Press the ID button on the front panel to switch on the system identification LEDs. I For more information, see section "Indicators on the front panel" on page 422 .

Using the ID icon in the iRMC web interface К Log in to the iRMC S5 web interface. The icon that represents the ID indicator LED resides on the right of the menu bar. Its color symbolizes its status: blue : the ID LED is on. grey : the ID LED is off К Click the icon to switch the ID indicator LED on or off. Using ServerView Operations Manager К In ServerView Operations Manager Single System View press the Locate button in the title bar to switch on the ID indicators. RX2530 M4 Upgrade and Maintenance Manual 81