fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Basic software procedures К During POST, press [F12] and select the connected USB stick as boot device. The system will detect the USB stick. К Choose the Recovery_L option from the update tool menu to start the iRMC update process. V CAUTION! Do not interrupt the iRMC upgrade process after it has started. If the process is interrupted, the iRMC BIOS may be permanently corrupted. I If the iRMC does not work after flashing, disconnect the system from the mains and reconnect it again. К Shut down the server by pressing the power On/Off button. К Disconnect the server from the mains to exit the iRMC recovery state.

5.2.2 Verifying system information backup/restore To avoid the loss of non-default settings when replacing the system board, a backup copy of important system configuration data is automatically stored from the system board NVRAM to the Chassis ID EPROM. After replacing the system board the backup data is restored from the Chassis ID board to the new system board. In order to verify whether the backup or restore process has been successful, check the System Event Log (SEL) using the ServerView Operations Manager (see also section "Viewing and clearing the System Event Log (SEL)" on page 95 ).

After replacing the system board К Check the SEL log files as described in section "Viewing and clearing the System Event Log (SEL)" on page 95 to verify whether the backup data on the Chassis ID EPROM has been restored to the system board: Chassis IDPROM: Motherboard Exchange detected Chassis IDPROM: BMC FW restore successful Chassis IDPROM: BIOS restore successful 84 Upgrade and Maintenance Manual RX2530 M4