-100 Code Description Corrective Actions 14,129 Toggle Head failure 1. Check physical position of head at failure. 2. Ensure toggle bar aligns with toggle stops. 3. Inspect top layer of model for part shift. 4. If any of above indicate a failure, Cycle Power and resend part. 5. Remove head cover, Verify that you can manually toggle the head. and check liquefier inlets for excessive material build up. Remove if present. 6. Check and reseat connectors/pins on J506 on the I/O card and J301 on the Head Board. 7. Reseat toggle connector on the Head Board. 8. Check Model and Support Toggle LED's on PDB. Verify high and low states. • On head board for toggle signal: TP201-Model; TP101-Support 9.
Using Tera Term run AH to toggle the head. Monitor system movement to help determine root cause of issue. 10. Replace Toggle Sensor Board. 11. Replace Head Board. 12. Replace Toggle Head assembly. 14,130 Temperature setback is active 1. Cycle power. 14,131 Toggle when head motor is running 1. Check Model and Support Toggle LED's on PDB. Verify high and low states. • On head board for toggle signal: TP201- Model; TP101-Support 2. Reseat connectors on the Head Board. 3. Replace Toggle Sensor Board. 4. Replace Head Board. 5. Replace Umbilical Cable. 14,132 UPS low power 1. UPS is shutting down. Check UPS and AC power.