-101 Code Description Corrective Actions 14,133 Head liquefier is not heating up 1. Liquefier T/C may be crushed. Test using meter. • If crushed, reading will be 0 Ohms between pin 1 and ground. 2. If head board with LED’s is present, check model and support 120VDC LEDs at head board. • If both model (upper) and support (lower) LEDs are illuminated, head heater is bad. Replace head. • If only the model LED (lower) is illumi- nated, replace the 120VDC power sup- ply • If only the support LED (upper) is illumi- nated, replace the power distribution board 3. If head board with LED’s is not present, use volt meter to check for 120 VDC at head board.
• If 120VDC present at both model and support side, heater is bad. Replace head. • If no 120VDC at support side, replace 120VDC power supply. • If no 120VDC at model side, replace power distribution board. 4. The umbilical cable to the heater is broken or has a bad connector. 5. Make sure the machine is plugged directly into a wall outlet. 6. Check the thermocouple connectors, heater connectors. 7. Verify that hard drive has not lost its .CAL values. If values are lost, download .CAL files. 14,134 Invalid packet size Software use only 14,135 Initialization failure 1. See LE (List Errors) output at end of CFG File.
14,136 Invalid state for operation Attempt to program firmware when system is not in upgrade mode. 1. Cycle power. 2. Reinstall upgrade. 14,137 MCB Communication error. Failure in command/ response protocol with MCB. 1. Power Off. 2. Check/Replace MCB cables (Reseat while powered down). 3. Power On. 4. Reload material. 5. Replace carrier. 6. Use LE command with Tera Term. 7. Replace material bay.