HP — Major Codes with Minor Codes

-102 Code Description Corrective Actions 14,138 MCB Firmware error: Error upgrading firmware. (possibly mismatched firmware/hardware versions) 1. Cycle power. 2. Reinstall upgrade. 14,139 MCB not present : No MCB available on the system. WARNING: Always power down system completely before connecting or disconnecting the Material Bay Cables. 1. Power down. 2. Reseat material bay cables. 3. Replace material bay cables. 4. Replace material bay. 5. Replace PDB or controller board. 6. Replace 24VDC power supply. 14,140 MCB end of filament event. End of filament detected when loading carrier. 1. Cycle power. 14,141 MCB filament loaded event.

Attempted to retract filament while it is loaded in the head. 1. Cycle power. 14,142 Auto purge detect failure. Failed to detect any material purge after loading. Software use only. 14,143 Model filament not present at EOF switch. Currently unused. Software use only. 14,144 Support filament not present at EOF switch. Currently unused. Software use only. 14,145 Model filament not present at FP switch. Currently unused. Software use only. 14,146 Support filament not present at FP switch. Currently unused. Software use only.