-112 3. Intermittent LOE - Head Motor - Intermittent tip plug 1. Check for loose heater block clamp screws. 2. Make sure the head connectors are seated properly. 3. Check air plenum for: proper hose connection; properly seating; cracks or damage. 4. Check to make sure head blower fan hose is connected to blower. 5. If extrusion fails on first layer a. If using a used modeling base, retry with a new one b. Rerun Z calibration 6. Plugged Liquefier - replace tips. 7. Inspect model for excessive overfill. a. Toolpaths should not overlap by more than 50%. If so, reorient and reprocess STL. b. If model curl has caused the part to contact the tip, reprocess part with less dense fill.
Re-run tip Z cal if part is separating from supports 8. Check idler wheel gap. 9. Check liquefier alignment. 10. Head idler spring is deformed or installed improperly. Replace head idler spring. 11. Possible head temperature issue a. Replace head board and TC Amp board. b. Replace toggle head assembly. 12. Head motor power wires or encoder failure - replace toggle head 13. Blower fan not supplying enough air flow - weak or stalling. Replace fan. 14. Replace umbilical cable 15. Replace controller board 16. In case of Z shift: a. Realign Z guide rods. b. Replace Z motor and leadscrew. c. Replace Z assembly. 4. Part Geometry Failure - Model or support features fell over 1.
Reorient, reprocess and resubmit the part 2. Run Z calibration 3. Replace tip shields and tip wipe assembly 4. If part has shifted in X or Y, refer to part quality section, part shift subsection. 5. In case of Z shift: a. Realign Z guide rods. b. Replace Z motor and leadscrew. c. Replace Z assembly.